Products

ABB NFZB22E-21 24-60V50/60HZ 20-60VDC CONTACTOR RELAY NFZB22E21

Product Code: NFZB22E21

  • Compact design Versatile power compatibility accomodates various power sources Meets stringent stnadards (IEC 60947-5-1, IEC 60077-1/-2, EN 50155) ensuring reliable performance Energy-efficient operation Enhanced safety and fire compliance
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Mounting Type DIN Rail / Screw
Brand ABB
Product Type NFZB Contactor Relay
Actuating Voltage Type AC/DC
Auxiliary Contacts 2NO, 2NC
Connection Type Screw Connection for Auxiliary Circuit
No. of Normally-closed Auxiliary Contacts 2
No. of Normally-open Auxiliary Contacts 2
Operating Voltage AC (V) 690
Rated Control Circuit Voltage AC (V) 24 - 60
Rated Control Circuit Voltage DC (V) 20 - 60
Rated Control Supply Voltage AC (V) 24
Rated Control Supply Voltage DC (V) 20
Rated Impulse Withstand Voltage (kV) 6
Rated Operational Current (A) 3
Rated Operational Current AC-15 400V (A) 3
Rated Operational Voltage AC (V) 690
Rated Supply Voltage AC (V) 24
Dimensions (mm) 45W x 86H x 86D
Standards and Approvals IEC 60947-5-1, EN 60947-5-1

Description

NFZB contactor relays comply with the latest railway rolling stock standards and allow installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They are used for switching auxiliary and control circuits. Improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C. Meet all main rollling stocks standards: IEC 60947-4-1, IEC 60947-5-1, IEC 60077-1/-2 and applicable parts of EN 50155 standards, shocks and vibration withstand conforming to IEC 61373 cat. 1, class B. Reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2, HL3 hazard levels) in group mounting. Reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation. Electronic coil interface handling large DC voltage fluctuation voltage, including several Uc DC control voltages used for battery supply and accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data). Wide range of auxiliary contact blocks for front and side mounting.