ABB E4H440WC30K ACB W/Fixed Part 1600-4000A 4-P 100kA 30VAC/DC Shunt Closing E4.2 Ekip Touch LSIG

Product Code: E4H440WC30K

  • Automatic ACB for 1600-4000 A applications
  • Rated voltage up to 690 VAC
  • High breaking capacity of 100 kA
  • Ekip Touch LSIG trip unit included
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Circuit Breaker
Brand ABB
Breaking Capacity 100 kA
Component Type Withdrawable
Frame Size E4.2
Number of Poles 4
Power Loss 900 W
Rated Current 1600-4000 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 85 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When it comes to ensuring the reliability and safety of your electrical systems, selecting the right Automatic Air Circuit Breaker (ACB) is crucial. This particular ACB offers a blend of robust performance and compliance with international standards, making it suitable for various industrial and commercial applications.</p><p>This ACB features a rated current range between 1600 to 4000 Amps, providing flexibility for different load requirements. It operates efficiently at a rated voltage of 690 VAC, which is well-suited for most high-demand environments. Furthermore, its impressive breaking capacity of 100 kA ensures that it can handle significant fault conditions without compromising system integrity.</p><p>Safety and durability are enhanced by its rated impulse withstand voltage of 12 kV and rated insulation voltage of 1000 VAC. These specifications underscore its ability to endure transient over-voltages and provide reliable insulation under normal operating conditions.</p><p>The trip unit integrated into this ACB is the Ekip Touch LSIG type, offering advanced protection features such as long-time (L), short-time (S), instantaneous (I), and ground fault (G) protections. This comprehensive protection suite helps prevent damage from overloads or short circuits while minimizing downtime due to maintenance or unexpected trips.</p><p>In terms of physical configuration, this ACB comes in a frame size E4.2 with a horizontal rear spread terminal type, facilitating straightforward installation in various panel setups. The four-pole design further enhances application versatility across three-phase systems with neutral connections.</p><p>Additionally, this device adheres to IEC 309 standards and approvals, reflecting its compliance with globally recognized benchmarks for safety and performance in electrical installations.</p><p>Power loss stands at 900 Watts during operation—an important consideration when evaluating energy efficiency within your setup.</p><p>Overall, this Automatic ACB offers an optimal balance between performance capabilities and operational safety requirements. Its comprehensive feature set makes it an excellent choice for professionals seeking reliability in demanding environments while adhering strictly to international standards.</p>