Products

ABB E6H363WM120K ACB W/Fixed Part 2520-6300A 3-P 100kA 100-130VAC/DC Motor Operator E6.2 Ekip Touch LSIG

Product Code: E6H363WM120K

  • Motor operated air circuit breaker
  • Rated current: 2520-6300 A
  • Breaking capacity: 100 kA
  • Ekip Touch LSIG trip unit
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Circuit Breaker
Brand ABB
Breaking Capacity 100 kA
Component Type Withdrawable
Frame Size E6.2
Number of Poles 3
Power Loss 1550 W
Rated Current 2520-6300 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 100 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When selecting a motor-operated air circuit breaker (ACB) for industrial or commercial applications, it&amp;#39;s crucial to consider specifications that align with your operational needs. This product is designed to meet demanding environments and offers robust performance across various parameters.</p><p>The ACB caters to a broad range of current requirements, with a rated current spanning from 2520 A to 6300 A. It ensures reliable operation under high current conditions, making it suitable for large-scale industrial setups. The rated voltage stands at 690 VAC, which covers most standard applications within the industry.</p><p>Safety and reliability are paramount in any electrical system. This ACB boasts a rated impulse withstand voltage of 12 kV and an insulation voltage of 1000 VAC, providing strong protection against overvoltage conditions. Furthermore, its short time withstand current rating is an impressive 100 kA, ensuring resilience during fault conditions without compromising system integrity.</p><p>Equipped with the Ekip Touch LSIG trip unit, this breaker offers advanced protection features including long-time (L), short-time (S), instantaneous (I), and ground fault (G) protections. Such comprehensive coverage helps prevent damage due to overloads or faults while maintaining seamless continuity of service.</p><p>The frame size is designated as E6.2 and accommodates three poles—ideal for balanced load distribution across phases in three-phase systems. With a horizontal rear spread terminal type, installation flexibility is enhanced, allowing easy integration into existing setups without significant modifications.</p><p>Efficiency considerations are also addressed with a power loss specification of 1550 W. While power loss is inevitable in electrical components, this figure indicates optimized design for energy management within the system&amp;#39;s lifecycle.</p><p>Compliant with IEC 309 standards and approvals, this ACB adheres to international benchmarks for safety and performance reliability—a critical factor when operating in diverse regulatory environments like Australia’s stringent compliance landscape.</p><p>In summary, this motor-operated ACB combines high capacity handling with sophisticated protection features suitable for heavy-duty applications. Its adherence to international standards further assures quality and dependability in operation.</p>