ABB E6H450WC120K ACB W/Fixed Part 2000-5000A 4-P 100kA 110-120VAC/DC Shunt Closing E6.2 Ekip Touch LSIG

Product Code: E6H450WC120K

  • Automatic ACB with 2000-5000 A range
  • Rated impulse withstand voltage of 12 kV
  • Ekip Touch LSIG trip unit for reliability
  • Breaking capacity up to 100 kA
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Circuit Breaker
Brand ABB
Breaking Capacity 100 kA
Component Type Withdrawable
Frame Size E6.2
Number of Poles 4
Power Loss 850 W
Rated Current 2000-5000 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 100 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When considering robust and reliable solutions for electrical distribution, this Automatic Air Circuit Breaker (ACB) stands out as a formidable option. Designed for industrial and commercial applications, it offers a comprehensive range of features tailored to meet demanding technical requirements.</p><p>The ACB is engineered with a rated current capacity ranging from 2000 to 5000 A, making it suitable for various heavy-duty applications. It operates efficiently at a rated voltage of 690 VAC and provides a rated insulation voltage of up to 1000 VAC. These specifications ensure the breaker can handle significant electrical loads while maintaining safety and reliability.</p><p>Safety is further enhanced by its impressive rated impulse withstand voltage of 12 kV and a short-time withstand current rating of 100 kA. This ensures the circuit breaker&amp;#39;s resilience against transient over-voltages and short circuits, providing peace of mind in high-stress environments.</p><p>One notable feature is the Ekip Touch LSIG trip unit, which offers advanced protection functions including long-time (L), short-time (S), instantaneous (I), and ground fault (G) protections. This intelligent system allows for precise adjustments tailored to specific application needs, ensuring optimal performance while minimizing downtime.</p><p>The frame size E6.2 supports its robust construction, complemented by horizontal rear spread terminals that facilitate easy integration into existing systems or new installations. Its four-pole design adds an extra layer of versatility for balanced three-phase networks with neutral considerations.</p><p>In terms of efficiency, the power loss is maintained at 850 W under full load conditions—an important factor when assessing operational costs over time. The breaking capacity matches the short-time withstand current at 100 kA, offering consistent performance during fault conditions.</p><p>Compliance with IEC 309 standards underscores its quality assurance and suitability within international markets—a critical consideration when adhering to stringent regulatory requirements in Australia or globally.</p><p>This Automatic ACB represents an excellent balance between performance, safety, and compliance for those seeking reliable solutions in their electrical infrastructure projects.</p>