ABB E1N412WO30K Low Voltage ACB W/Fixed Part 500-1250A 4-P 66kA 30VAC/DC Shunt Opening E1.2 Ekip Touch LSIG

Product Code: E1N412WO30K

  • Automatic ACB with 4 poles
  • Rated current range: 500-1250 A
  • Breaking capacity of 66 kA
  • Ekip Touch LSIG trip unit
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Low Voltage Air Circuit Breaker With Fixed Part
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E1.2
Number of Poles 4
Power Loss 244 W
Rated Current 500-1250 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 50 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

When it comes to ensuring reliable and efficient power distribution in industrial and commercial settings, selecting the right Automatic Air Circuit Breaker (ACB) is crucial. This ACB model offers a robust solution with its versatile features tailored for demanding environments. The ACB boasts a rated current range of 500-1250 A, making it adaptable for various applications. It operates effectively at a rated voltage of 690 VAC, providing the necessary flexibility for diverse electrical systems. With a rated insulation voltage of 1000 VAC and an impressive rated impulse withstand voltage of 12 kV, this breaker is designed to handle high-stress conditions while maintaining safety standards. One of the standout features is its breaking capacity of 66 kA, which ensures that even in scenarios involving significant fault currents, the system remains protected. Complementing this capability is its rated short time withstand current of 50 kA, allowing it to endure brief overloads without compromising performance. Equipped with the Ekip Touch LSIG trip unit, users benefit from advanced protection functionalities including long-time, short-time, instantaneous, and ground fault protection. This comprehensive protection scheme ensures that your electrical infrastructure remains safeguarded against various fault conditions. Designed with practicality in mind, this ACB features a frame size designated as E1.2 and includes four poles suitable for balanced load distribution across phases. The horizontal rear spread terminal type facilitates straightforward installation and integration into existing setups. Adhering to IEC 309 standards underscores its compliance with international safety regulations—an assurance for those prioritizing reliability and quality in their electrical components. Despite its powerful capabilities, the product maintains efficiency with a power loss rating of just 244 W—a testament to its design aimed at minimizing energy wastage while delivering optimal performance. In conclusion, this Automatic ACB presents itself as a dependable choice for professionals seeking durability combined with advanced protective functions within their power distribution systems. Its alignment with global standards further solidifies its place as an essential component in any modern electrical setup looking to balance performance with safety efficiently.