ABB E2H425WC250K ACB W/Fixed Part 1000-2500A 4-P 100kA 240-250VAC/DC Shunt Closing E2.2 Ekip Touch LSIG

Product Code: E2H425WC250K

  • Automatic ACB with 1000-2500 A rating
  • Handles up to 85 kA short-time current
  • Ekip Touch LSIG trip unit for precision control
  • Rated voltage of 690 VAC, insulation at 1000 VAC
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Circuit Breaker
Brand ABB
Breaking Capacity 100 kA
Component Type Withdrawable
Frame Size E2.2
Number of Poles 4
Power Loss 550 W
Rated Current 1000-2500 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 85 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

When it comes to ensuring reliability and safety in industrial and commercial electrical systems, choosing the right Automatic Air Circuit Breaker (ACB) is crucial. This ACB offers a robust solution designed to meet demanding requirements with precision and efficiency. This model operates within a rated current range of 1000-2500 A, making it versatile for various applications. It is engineered to handle a rated voltage of up to 690 VAC, providing flexibility across different electrical setups. The rated impulse withstand voltage stands at an impressive 12 kV, ensuring resilience against transient overvoltages. The circuit breaker boasts a rated insulation voltage of 1000 VAC and is capable of enduring short-time currents up to 85 kA. Its breaking capacity reaches 100 kA, highlighting its ability to interrupt high fault currents effectively—an essential feature for maintaining system integrity under fault conditions. Equipped with the Ekip Touch LSIG trip unit, this ACB delivers advanced protection functions including long-time (L), short-time (S), instantaneous (I), and ground-fault protection (G). This comprehensive protection ensures operational safety while minimizing downtime due to faults. With power loss documented at 550 W, the design focuses on energy efficiency without compromising performance. The frame size E2.2 provides a compact yet sturdy housing that can accommodate diverse installation needs. Designed as a four-pole device with horizontal rear spread terminals, this product simplifies integration into existing systems while maintaining reliable connectivity. Compliance with IEC 309 standards affirms its adherence to international safety and performance benchmarks. Overall, this Automatic ACB presents itself as a dependable choice for professionals seeking reliability and adaptability in their electrical infrastructure solutions.