ABB E2H425WO30K ACB W/Fixed Part 1000-2500A 4-P 100kA 30VAC/DC Shunt Opening E2.2 Ekip Touch LSIG

Product Code: E2H425WO30K

  • Automatic ACB with 4 poles
  • Rated current: 1000-2500 A
  • Breaking capacity of 100 kA
  • Ekip Touch LSIG trip unit
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Circuit Breaker
Brand ABB
Breaking Capacity 100 kA
Component Type Withdrawable
Frame Size E2.2
Number of Poles 4
Power Loss 550 W
Rated Current 1000-2500 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 85 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

When selecting an Automatic Air Circuit Breaker (ACB) for industrial or commercial applications, understanding the specifications is crucial to ensure it meets your technical requirements. This ACB offers a robust solution with its versatile features and reliable performance. The ACB supports a rated current range from 1000 to 2500 A, making it suitable for various high-demand electrical systems. Its rated impulse withstand voltage is set at 12 kV, providing excellent protection against transient overvoltages typically caused by lightning strikes or switching surges. With a rated insulation voltage of 1000 VAC, this circuit breaker ensures safe operation within its intended application environment. It also boasts a rated short-time withstand current of 85 kA, allowing it to handle significant fault conditions without compromising safety or functionality. Operating at a rated voltage of up to 690 VAC, this ACB can be integrated into many industrial power systems. The inclusion of the Ekip Touch LSIG trip unit enhances its capability by offering advanced protection features such as long-time, short-time, instantaneous, and ground fault protection settings tailored to meet specific operational needs. Power loss is an important consideration in any electrical device; this model has been optimized with a power loss rating of just 550 W. It maintains efficiency while ensuring dependable operation across all four poles. The breaking capacity stands out at an impressive 100 kA. This feature provides reassurance that the circuit breaker can safely interrupt high fault currents without damage or risk to connected equipment and personnel. Designed with a frame size of E2.2 and horizontal rear spread terminals, installation flexibility is enhanced while maintaining compliance with IEC 309 standards and approvals—a testament to its quality and reliability in demanding environments. In summary, this Automatic ACB combines essential features such as high current handling capacity, comprehensive protection settings via the Ekip Touch LSIG trip unit, efficient power management with minimal losses—all wrapped in a durable design that adheres strictly to international standards. Whether you're upgrading existing infrastructure or planning new installations in Australia’s diverse industrial landscape—this product delivers on every front without compromise on safety or performance.

Documents

  • IPD Product Catalogue

    IPD Product Catalogue V17
Products to compare:
Comparing Products