Products

ABB E4N432WM48K ACB W/Fixed Part 1280-3200A 4-P 66kA 48-60VAC/DC Motor Operator E4.2 Ekip Touch LSIG

Product Code: E4N432WM48K

  • Motor operated ACB with 1280-3200 A rating
  • Handles up to 66 kA short circuit current
  • Ekip Touch LSIG trip unit for advanced protection
  • Rated voltage of 690 VAC, insulation at 1000 VAC
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Circuit Breaker
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E4.2
Number of Poles 4
Power Loss 743 W
Rated Current 1280-3200 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 66 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

When it comes to ensuring the reliability and safety of electrical systems in industrial and commercial settings, selecting the right Air Circuit Breaker (ACB) is crucial. This Motor Operated ACB is engineered to meet demanding operational requirements with a range of features designed for robust performance. One of the standout aspects of this ACB is its rated current capacity, which spans from 1280 A to 3200 A. This flexibility allows it to handle varying loads effectively, making it suitable for a wide array of applications. The device operates efficiently under high voltage conditions, boasting a rated insulation voltage of 1000 VAC and a rated voltage of 690 VAC. Safety and durability are further emphasized with its rated impulse withstand voltage at 12 kV and a substantial short time withstand current rating at 66 kA. These specifications ensure that the breaker can endure transient overvoltages and short-circuit conditions without compromising system integrity. The Ekip Touch LSIG trip unit integrated into this ACB provides advanced protection by monitoring various parameters such as overloads, short circuits, earth faults, and more. This intelligent functionality ensures timely intervention during fault conditions while minimizing downtime. Designed with practicality in mind, this model features four poles and utilizes horizontal rear spread terminals for efficient connectivity in your setup. Its breaking capacity matches its short time withstand current at 66 kA, reinforcing its capability to interrupt fault currents effectively. Despite its powerful performance capabilities, the power loss is maintained at an optimal level of 743 W—demonstrating an efficient energy management approach within your electrical distribution network. Conforming to IEC 309 standards ensures that this product meets international safety benchmarks—a testament to quality assurance you can trust in critical installations. With these comprehensive features encapsulated within the E4.2 frame size design, this Motor Operated ACB stands as a reliable choice for those seeking dependable circuit protection solutions tailored specifically for rigorous environments where precision matters most.

Documents

  • IPD Product Catalogue

    IPD Product Catalogue V17
Products to compare: