Products

ABB E4N440WO250K ACB W/Fixed Part 1600-4000A 4-P 66kA 240-250VAC/DC Shunt Opening E4.2 Ekip Touch LSIG

Product Code: E4N440WO250K

  • Automatic ACB with 1600-4000 A current range
  • High withstand voltage of 12 kV
  • Ekip Touch LSIG trip unit for precise control
  • Rated short time withstand current: 66 kA
  • Compliant with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Size of Frame E4.2
G (0.1 to 1 x In) - I4 (A) 400-4000
I (1.5 to 15 x In) - I3 (A) 6000-60000
L (0.4 to 1 x In) - I1 (A) 1600-4000
No. of Poles 4P
Power Loss (W) 900
Rated Current (A) 4000
Rated Impulse Withstand Voltage (kV) 12
Rated Insulation Voltage AC (V) 1000
Rated Operational Voltage AC (V) 690
Rated Short-time Withstand Current - Icw (kA/1s) 66
Rated Uninterrupted Current - Iu (A) 4000
S (0.6 to 10 x In) - I2 (A) 2400-40000
Breaking Capacity 415V AC - Icu (kA) 66
Poles 4P
Breaking Capacity (kA) 66 @415V AC
Current Rating (A) 4000
Trip Unit - Electronic EKIP Touch LSIG
AC Voltage (V) 690
Frame E4.2
Icw (kA/1s) - Short-time Withstand Current Rating 66
Iu - Uninterrupted Current Rating (A) 4000
Product Type Circuit Breaker
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E4.2
Number of Poles 4
Power Loss 900 W
Rated Current 1600-4000 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 66 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

The ACB E4.2N is a 4-pole circuit breaker with a rated current (In) of 4000A. It has an Icu rating of 66kA at 415V AC, indicating its ability to interrupt short-circuit currents. The circuit breaker also has a rated short-time withstand current, Icw (1s), of 66kA. The ACB E4.2N features a withdrawable auto EKIP Touch LSIG trip unit with horizontal rear terminals. It is equipped with a shunt opening release that operates at 240-250V AC/DC. The circuit breaker comes complete with WMP+FP components. This circuit breaker is designed for engineers who require a high-rated current and reliable performance in interrupting short-circuit currents. The withdrawable feature and LSIG trip unit provide convenience and flexibility in maintenance and operation. With the shunt opening release, it ensures safe disconnection during fault conditions.