Products

ABB E6H450WO30K ACB W/Fixed Part 2000-5000A 4-P 100kA 30VAC/DC Shunt Opening E6.2 Ekip Touch LSIG

Product Code: E6H450WO30K

  • Automatic ACB with 2000-5000 A range
  • Withstands impulse voltage of 12 kV
  • Rated short time withstand current: 100 kA
  • Ekip Touch LSIG trip unit for precision control
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Size of Frame E6.2
G (0.1 to 1 x In) - I4 (A) 500-5000
I (1.5 to 15 x In) - I3 (A) 7500-75000
L (0.4 to 1 x In) - I1 (A) 2000-5000
No. of Poles 4P
Power Loss (W) 850
Rated Current (A) 5000
Rated Impulse Withstand Voltage (kV) 12
Rated Insulation Voltage AC (V) 1000
Rated Operational Voltage AC (V) 690
Rated Short-time Withstand Current - Icw (kA/1s) 100
Rated Uninterrupted Current - Iu (A) 5000
S (0.6 to 10 x In) - I2 (A) 3000-50000
Breaking Capacity 415V AC - Icu (kA) 100
Poles 4P
Breaking Capacity (kA) 100 @415V AC
Current Rating (A) 5000
Trip Unit - Electronic EKIP Touch LSIG
AC Voltage (V) 690
Frame E6.2
Icw (kA/1s) - Short-time Withstand Current Rating 100
Iu - Uninterrupted Current Rating (A) 5000
Product Type Circuit Breaker
Brand ABB
Breaking Capacity 100 kA
Component Type Withdrawable
Frame Size E6.2
Number of Poles 4
Power Loss 850 W
Rated Current 2000-5000 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 100 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

When selecting an Automatic Air Circuit Breaker (ACB) for industrial or commercial applications, the focus often lies on reliability and performance. This ACB model is designed to meet demanding electrical requirements with a rated current ranging from 2000 to 5000 A, making it suitable for high-capacity systems. The breaker features a robust rated impulse withstand voltage of 12 kV and a rated insulation voltage of 1000 VAC, ensuring superior protection against electrical surges and insulation failures. With a rated short-time withstand current of 100 kA, it can handle substantial fault currents without compromising system integrity. Operating at a rated voltage of up to 690 VAC, this ACB is versatile enough for diverse applications. Its trip unit, the Ekip Touch LSIG, offers advanced protection functions including long-time (L), short-time (S), instantaneous (I), and ground fault (G) protections. This ensures precise control over circuit interruptions based on specific power system conditions. The power loss stands at an efficient 850 W, minimizing energy wastage while maintaining operational efficacy. The device's four-pole configuration enhances its adaptability in three-phase systems with neutral conductors. For installation flexibility, the horizontal rear spread terminal type allows easy integration into existing setups without extensive modifications. Compliance with IEC 309 standards underscores its adherence to international safety and performance benchmarks. The frame size E6.2 indicates compatibility with various enclosure dimensions while maintaining structural durability under high-stress conditions. In summary, this Automatic ACB offers comprehensive protection and efficiency for your electrical infrastructure needs within its specified ratings—ensuring safety and reliability in critical operations.