ABB E1N316WO24K Low Voltage ACB W/Fixed Part 640-1600A 3-P 66kA 24VAC/DC Shunt Opening E1.2 Ekip Touch LSIG

Product Code: E1N316WO24K

  • Automatic ACB, 640-1600 A range
  • Ekip Touch LSIG trip unit for precision
  • Rated voltage up to 690 VAC
  • Breaking capacity of 66 kA
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Low Voltage Air Circuit Breaker
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E1.2
Number of Poles 3
Power Loss 400 W
Rated Current 640-1600 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 50 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When it comes to industrial and commercial electrical applications, the need for reliable and robust protection is paramount. The Automatic Air Circuit Breaker (ACB) in question stands out as a dependable choice for professionals seeking efficiency and safety in their electrical systems.</p><p>This ACB is designed with a rated current range of 640-1600 A, making it versatile enough to handle various load requirements within this spectrum. Its rated impulse withstand voltage of 12 kV ensures resilience against transient overvoltages, which are common challenges in industrial environments.</p><p>The breaker features a rated insulation voltage of 1000 VAC, providing adequate insulation strength for high-voltage applications. With a rated short time withstand current capacity of 50 kA, it offers substantial protection against potential fault currents that may occur over brief periods.</p><p>Operating at a rated voltage of 690 VAC, this circuit breaker is suitable for medium-voltage installations commonly found in industrial settings. The Ekip Touch LSIG trip unit enhances operational functionality by offering comprehensive protection features including long-time, short-time, instantaneous, and ground fault protections—crucial for maintaining system integrity.</p><p>Power loss during operation is measured at 400 W, indicating efficient energy management without compromising on performance. This attribute is particularly beneficial in minimizing operational costs while maintaining optimal safety standards.</p><p>The ACB&amp;#39;s design incorporates three poles and boasts an impressive breaking capacity of 66 kA. This ensures that even under severe fault conditions, the breaker can effectively interrupt the current flow to protect downstream equipment from damage.</p><p>With its frame size categorized as E1.2 and equipped with horizontal rear spread terminals, installation flexibility is enhanced—allowing seamless integration into existing setups or new designs with minimal hassle.</p><p>Adhering to IEC 309 standards underscores its compliance with international safety regulations—a critical factor when selecting components for high-stakes environments where reliability cannot be compromised.</p><p>This Automatic ACB presents itself as a well-rounded solution tailored for professionals who prioritize durability and precision engineering in their electrical infrastructure projects.</p>
Products to compare:
Comparing Products