ABB E1N316WOCM120K ACB W/Fixed Part 640-1600A 3-P 66kA 110-120VAC/DC Shunt Open/Close Motor Operator Ekip Touch LSIG

Product Code: E1N316WOCM120K

  • Motor operated ACB for reliable performance
  • Current range: 640-1600 A
  • Withstand voltage up to 12 kV
  • Breaking capacity of 66 kA
  • Ekip Touch LSIG trip unit for advanced protection
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Low Voltage Air Circuit Breaker With Fixed Part
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E1.2
Number of Poles 3
Power Loss 400 W
Rated Current 640-1600 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 50 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>For those in the industrial and commercial sectors looking for a reliable solution in circuit protection, this Motor Operated Air Circuit Breaker (ACB) offers robust performance tailored to meet demanding electrical requirements. Designed with versatility and safety in mind, this ACB is suitable for a range of applications due to its comprehensive technical specifications.</p><p>The rated current spans from 640 to 1600 A, providing flexibility for various operational needs. With a rated impulse withstand voltage of 12 kV and an insulation voltage of 1000 VAC, it ensures resilience against electrical surges and insulation failures. This makes it ideal for environments where stability and reliability are paramount.</p><p>Safety is further enhanced by its rated short time withstand current of 50 kA, allowing it to handle transient overcurrents without compromising its integrity. The breaker operates at a rated voltage of 690 VAC, aligning with standard industrial power systems.</p><p>Equipped with the advanced Ekip Touch LSIG trip unit, this ACB provides precise protection through adjustable settings that cater to specific load requirements. The integration of LSIG functionalities (Long-time, Short-time, Instantaneous, Ground fault) ensures comprehensive protection across different fault scenarios.</p><p>Efficiency is also considered with a power loss rating of just 400 W. This feature supports energy management strategies by minimizing unnecessary power consumption while maintaining performance standards.</p><p>The device features three poles and boasts a breaking capacity of 66 kA. This high breaking capacity means it&amp;#39;s designed to safely interrupt high fault currents without damage or hazard—an essential characteristic for maintaining system continuity in critical operations.</p><p>Sized within the E1.2 frame category, this ACB fits seamlessly into existing installations where space might be limited yet demands on performance remain high. Installation is simplified with horizontal rear spread terminals which facilitate straightforward connections and maintenance access.</p><p>Compliant with IEC 309 standards and approvals, users can trust that this product meets international benchmarks for safety and functionality—a crucial consideration when integrating new components into complex systems.</p><p>In summary, this Motor Operated ACB stands out as a dependable choice for professionals seeking durability combined with advanced protective features in their electrical distribution networks.</p>