ABB E1N38WOCM415K ACB W/Fixed Part 320-800A 3-P 66kA 380-415VAC Shunt Open/Close Motor Operator Ekip Touch LSIG

Product Code: E1N38WOCM415K

  • Motor operated ACB for reliable control
  • Handles 320-800A rated current
  • Ekip Touch LSIG trip unit included
  • 66kA breaking capacity ensures safety
  • Meets IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Low Voltage Air Circuit Breaker With Fixed Part
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E1.2
Number of Poles 3
Power Loss 100 W
Rated Current 320-800 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 50 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When considering the selection of a motor-operated air circuit breaker (ACB) for your industrial or commercial needs, it&amp;#39;s essential to focus on the technical specifications that ensure reliability and performance. This Motor Operated ACB is designed with precision to meet rigorous standards, providing robust protection and operational efficiency.</p><p>The device features a rated current range from 320 to 800 A, making it versatile for various applications requiring substantial power management. With a rated impulse withstand voltage of 12 kV, this ACB can handle high transient voltages effectively, ensuring safety and durability in fluctuating electrical environments.</p><p>Operating at a rated insulation voltage of 1000 VAC and a rated voltage of 690 VAC, this ACB is well-suited for heavy-duty operations where high voltage stability is crucial. It boasts an impressive breaking capacity of 66 kA which means it can interrupt significant fault currents without compromising system integrity.</p><p>Safety during short circuits is enhanced by its rated short time withstand current capability of 50 kA. This ensures that the breaker can sustain high fault currents momentarily while protecting downstream equipment from damage.</p><p>The trip unit integrated into this model is the Ekip Touch LSIG type. Known for its advanced technology, the Ekip Touch provides comprehensive protection with long-time (L), short-time (S), instantaneous (I), and ground fault (G) functions. This ensures precise control over various fault conditions while maintaining user-friendly operation through its intuitive interface.</p><p>Designed with practicality in mind, this ACB has three poles and fits within an E1.2 frame size—ideal for space-conscious installations without sacrificing performance. The terminal type is horizontal rear spread configuration which simplifies installation by allowing easy connections at the back of panels or enclosures.</p><p>In terms of compliance and safety assurances, this product adheres strictly to IEC 309 standards—a testament to its quality manufacturing processes and adherence to international benchmarks.</p><p>With a power loss rating at just 100 W under normal operating conditions, it offers efficient energy consumption—minimizing heat generation while maximizing longevity.</p><p>Overall, whether you&amp;#39;re upgrading existing systems or installing new ones across industrial settings like factories or commercial complexes such as data centers or shopping malls—this Motor Operated ACB delivers reliable performance backed by stringent standards compliance ensuring peace-of-mind operation throughout its lifecycle.</p>

Documents

  • IPD Product Catalogue

    IPD Product Catalogue V17