ABB E1N412WC30K Low Voltage ACB W/Fixed Part 500-1250A 4-P 66kA 30VAC/DC Shunt Closing E1.2 Ekip Touch LSIG

Product Code: E1N412WC30K

  • Automatic ACB for 500-1250 A applications
  • Handles up to 66 kA breaking capacity
  • Ekip Touch LSIG trip unit included
  • Rated voltage of 690 VAC, withstands 50 kA short time
  • Compliant with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Low Voltage Air Circuit Breaker With Fixed Part
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E1.2
Number of Poles 4
Power Loss 244 W
Rated Current 500-1250 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 50 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When it comes to ensuring the robustness and reliability of your electrical systems, selecting the right Automatic Air Circuit Breaker (ACB) is crucial. This ACB, designed for industrial and commercial applications, offers a comprehensive set of features tailored to meet demanding operational requirements.</p><p>The device supports a broad range of rated currents from 500 A to 1250 A, making it versatile enough to handle various load demands. With a rated voltage capacity of 690 VAC and an insulation voltage rating of up to 1000 VAC, this breaker is well-suited for high-voltage environments. Its ability to withstand impulse voltages up to 12 kV ensures resilience against transient overvoltages often encountered in industrial settings.</p><p>Safety and durability are paramount with its short time withstand current rated at 50 kA and breaking capacity pegged at an impressive 66 kA. These specifications highlight its capability to manage fault conditions effectively without compromising on performance or safety.</p><p>The unit incorporates the Ekip Touch LSIG trip unit, providing advanced protection functions including long-time (L), short-time (S), instantaneous (I), and ground fault (G) protections. This sophisticated trip unit enhances system reliability by offering precise control and monitoring capabilities.</p><p>Engineered with a frame size of E1.2 and featuring a horizontal rear spread terminal type, installation flexibility is assured. The four-pole configuration further adds to its adaptability across different system architectures.</p><p>Power loss is kept at a minimal level with just 244 W, optimizing energy efficiency while maintaining operational effectiveness—a critical factor for businesses looking to reduce energy consumption without sacrificing performance.</p><p>Compliance with IEC 309 standards underscores the product&amp;#39;s adherence to international quality benchmarks, ensuring peace of mind when integrating into existing infrastructures or planning new installations.</p><p>This Automatic ACB stands as a reliable choice for professionals seeking dependable circuit protection solutions that combine technical excellence with practical functionality—perfectly suited for those who prioritize facts over frills in their decision-making process.</p>