ABB E1N416WC250K Low Voltage ACB W/Fixed Part 640-1600A 4-P 66kA 240-250VAC/DC Shunt Closing E1.2 Ekip Touch LSIG

Product Code: E1N416WC250K

  • Automatic ACB with 4 poles
  • Rated current range: 640-1600 A
  • Breaking capacity of 66 kA
  • Ekip Touch LSIG trip unit
  • Complies with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Low Voltage Air Circuit Breaker With Fixed Part
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E1.2
Number of Poles 4
Power Loss 400 W
Rated Current 640-1600 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 50 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When selecting the right Automatic Air Circuit Breaker (ACB) for your industrial or commercial needs, it&amp;#39;s crucial to consider specifications that align with your operational demands. This ACB offers a robust solution, designed to handle a wide range of electrical challenges efficiently.</p><p>The rated current spans from 640 to 1600 A, making it versatile for various applications. With a rated impulse withstand voltage of 12 kV and an insulation voltage of 1000 VAC, this ACB is engineered to provide reliable performance under demanding conditions. It supports a rated voltage of up to 690 VAC, suitable for most industrial environments.</p><p>One key feature is its breaking capacity of 66 kA, ensuring it can effectively interrupt fault currents without compromising safety. The device also boasts a short time withstand current rating of 50 kA, providing assurance in its ability to manage temporary overloads and protect your system.</p><p>Equipped with the Ekip Touch LSIG trip unit, this ACB offers advanced protection features such as long-time (L), short-time (S), instantaneous (I), and ground fault (G) protection functions. This comprehensive protection suite enhances system reliability and minimizes downtime by quickly responding to fault conditions.</p><p>The power loss is rated at 400 W, reflecting efficient energy usage while maintaining high performance levels. Its four-pole configuration ensures balanced load distribution across phases, which is essential for maintaining system stability in three-phase networks.</p><p>Designed with practicality in mind, the horizontal rear spread terminal type facilitates straightforward installation and maintenance. Compatibility with IEC 309 standards underscores its adherence to international quality benchmarks and ensures compatibility within global systems.</p><p>The frame size E1.2 indicates a compact design that doesn&amp;#39;t compromise on capability or durability. Whether you&amp;#39;re upgrading existing infrastructure or implementing new installations, this ACB provides dependable operation tailored for mid-sized electrical frameworks.</p><p>In summary, this Automatic ACB combines high-rated capacities with intelligent protection features suitable for varied applications across industries looking for durable solutions compliant with rigorous standards.</p>