ABB E1N416WC48K Low Voltage ACB W/Fixed Part 640-1600A 4-P 66kA 48VAC/DC Shunt Closing E1.2 Ekip Touch LSIG

Product Code: E1N416WC48K

  • Automatic ACB with 4 poles
  • Rated current range: 640-1600 A
  • Breaking capacity of 66 kA
  • Ekip Touch LSIG trip unit included
  • Compliant with IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Low Voltage Air Circuit Breaker With Fixed Part
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E1.2
Number of Poles 4
Power Loss 400 W
Rated Current 640-1600 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 50 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When it comes to industrial and commercial applications, selecting the right Automatic Air Circuit Breaker (ACB) is crucial. This ACB, with its robust specifications, ensures reliability and efficiency for your electrical systems.</p><p>One of the standout features of this ACB is its wide range of rated current, from 640 to 1600 Amperes. This flexibility allows it to cater to various load requirements without compromising on performance. Its rated voltage stands at 690 VAC, making it suitable for diverse applications in different environments.</p><p>The breaker boasts a remarkable breaking capacity of 66 kA, ensuring that it can handle high fault currents effectively, providing safety and protection against electrical faults. Complementing this is its impressive rated short time withstand current of 50 kA, which enhances the system&amp;#39;s resilience during transient conditions.</p><p>Safety and durability are further assured with a rated impulse withstand voltage of 12 kV and a rated insulation voltage of 1000 VAC. These attributes ensure that the circuit breaker can endure electrical stresses while maintaining operational integrity.</p><p>Equipped with an Ekip Touch LSIG trip unit, this ACB offers advanced protection functionalities including long-time (L), short-time (S), instantaneous (I), and ground fault (G) protections. Such comprehensive coverage ensures optimal safeguarding against potential electrical anomalies.</p><p>The frame size E1.2 designates a compact yet sturdy structure capable of accommodating demanding industrial needs without taking up excessive space. With four poles available, the ACB supports balanced distribution across phases in three-phase systems.</p><p>Power loss is maintained at a minimal level with only 400 watts consumed during operation—an essential factor for energy efficiency considerations within large-scale installations.</p><p>Installation flexibility is provided through horizontal rear spread terminals which facilitate straightforward integration into existing setups or new projects alike.</p><p>Adhering to IEC standards specifically IEC 309 underlines the product&amp;#39;s compliance with international quality benchmarks ensuring both safety and reliability in application scenarios worldwide.</p><p>In conclusion, this Automatic ACB provides an excellent balance between technical capability and practical functionality—a reliable choice for professionals seeking dependable circuit protection solutions tailored to rigorous industrial demands.</p>