ABB E2H325WM24K ACB W/Fixed Part 1000-2500A 3-P 100kA 24VAC/DC Motor Operator E2.2 Ekip Touch LSIG

Product Code: E2H325WM24K

  • Motor operated ACB for reliable control
  • Rated current range: 1000-2500 A
  • High breaking capacity of 100 kA
  • Ekip Touch LSIG trip unit included
  • Meets IEC 309 standards
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Air Circuit Breaker
Brand ABB
Breaking Capacity 100 kA
Component Type Withdrawable
Frame Size E2.2
Number of Poles 3
Power Loss 550 W
Rated Current 1000-2500 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 85 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When assessing the suitability of a Motor Operated Air Circuit Breaker (ACB) for your industrial or commercial needs, it&amp;#39;s crucial to delve into the technical specifics that ensure compatibility with your operational requirements. This particular ACB offers a robust solution designed to handle demanding environments, thanks to its comprehensive set of features.</p><p>With a rated current ranging from 1000 to 2500 Amperes, this ACB provides flexibility and reliability for various applications. Its rated impulse withstand voltage is set at 12 kV, ensuring resilience against transient overvoltages which are common in electrical systems. Moreover, it boasts a rated insulation voltage of 1000 VAC, offering solid protection against electrical faults.</p><p>The ACB&amp;#39;s breaking capacity stands at an impressive 100 kA, making it suitable for high-demand scenarios where fault currents need effective interruption. Coupled with a rated short-time withstand current of 85 kA, this breaker is engineered to endure significant stress without compromising performance or safety.</p><p>In terms of control and precision, the Ekip Touch LSIG trip unit offers advanced functionality. It provides comprehensive protection by monitoring long-time (L), short-time (S), instantaneous (I), and ground fault (G) conditions—critical for maintaining system integrity and preventing damage due to overloads or faults.</p><p>Power loss is another important consideration in any electrical setup; this model presents a power loss figure of 550 W. While power loss inevitably occurs in all circuit breakers during operation, understanding these metrics helps in planning energy efficiency strategies within your installation.</p><p>This three-pole device fits into the E2.2 frame size category and features horizontal rear spread terminals—ideal for setups requiring compact yet accessible configurations. The design facilitates straightforward integration into existing systems while adhering strictly to IEC 309 standards and approvals—a testament to its adherence to international quality benchmarks.</p><p>In summary, this Motor Operated ACB provides dependable performance characterized by robust construction and detailed engineering suited for rigorous use cases across industrial sectors. Whether you&amp;#39;re upgrading existing infrastructure or implementing new installations, these specifications ensure you have the data needed to make an informed decision tailored precisely to your technical demands.</p>
Products to compare:
Comparing Products