ABB E4N340WM30K ACB W/Fixed Part 1600-4000A 3-P 66kA 24-30VAC/DC Motor Operator E4.2 Ekip Touch LSIG

Product Code: E4N340WM30K

  • Motor-operated ACB, 1600-4000 A range
  • Rated voltage up to 690 VAC
  • Ekip Touch LSIG trip unit included
  • Withstands impulse voltage of 12 kV
  • Horizontal rear spread terminals
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Circuit Breaker
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E4.2
Number of Poles 3
Power Loss 900 W
Rated Current 1600-4000 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 66 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When selecting a motor-operated air circuit breaker (ACB) for your industrial or commercial application, it&amp;#39;s crucial to consider the technical specifications that align with your operational needs. This particular ACB offers a robust solution with its impressive range of features and capabilities.</p><p>The rated current for this ACB spans from 1600 to 4000 amperes, providing flexibility across various applications where different load requirements might be encountered. The device is designed to handle high power demands while maintaining efficiency and safety.</p><p>With a rated impulse withstand voltage of 12 kV, this ACB is well-equipped to manage transient over-voltages that can occur in electrical systems. Additionally, the rated insulation voltage stands at 1000 VAC, ensuring reliable performance under standard operating conditions.</p><p>This model excels in short-circuit scenarios thanks to its rated short-time withstand current and breaking capacity both set at an impressive 66 kA. Such specifications ensure it can effectively protect circuits by interrupting fault currents swiftly and safely.</p><p>Operating at a rated voltage of 690 VAC, this ACB is suitable for medium-voltage applications commonly found in industrial settings. It features an Ekip Touch LSIG trip unit which provides advanced protection functionalities including overload (L), short-circuit (S), instantaneous (I), and ground fault (G) protections—essential for safeguarding both equipment and personnel.</p><p>The power loss associated with this unit is measured at 900 watts. While all electrical devices incur some level of power loss during operation, knowing this figure helps you calculate energy efficiency within your system design.</p><p>Designed with three poles, the ACB ensures consistent distribution of electricity across phases in three-phase systems—a common configuration in industrial environments. The frame size of E4.2 indicates its physical dimensions are optimized for space-saving installations without compromising on performance or reliability.</p><p>Featuring horizontal rear spread terminals, installation becomes straightforward as it allows efficient connections within switchgear assemblies or panels—ideal when space constraints are present or when retrofitting existing setups.</p><p>Compliance with IEC 309 standards underscores the product&amp;#39;s adherence to international quality and safety benchmarks—a reassuring factor when integrating into critical infrastructure projects where reliability cannot be compromised.</p><p>This motor-operated ACB stands out as a dependable choice offering substantial protective measures necessary for demanding electrical networks frequently faced by Australian industries today.</p>

Documents

  • IPD Product Catalogue

    IPD Product Catalogue V17