ABB E4N340WOCM30K ACB W/Fixed Part 1600-4000A 3-P 66kA 30VAC/DC Shunt Open/Close Motor Operator Ekip Touch LSIG

Product Code: E4N340WOCM30K

  • Motor operated ACB with 1600-4000 A range
  • Withstands impulse voltage up to 12 kV
  • Insulation voltage rated at 1000 VAC
  • Short time withstand current of 66 kA
  • Ekip Touch LSIG trip unit for protection
In Stock Low Stock Out Of Stock Please See Attributes

Specifications

Product Type Air Circuit Breaker
Brand ABB
Breaking Capacity 66 kA
Component Type Withdrawable
Frame Size E4.2
Number of Poles 3
Power Loss 900 W
Rated Current 1600-4000 A
Rated Impulse Withstand Voltage 12 kV
Rated Insulation Voltage 1000 VAC
Rated Short Time Withstand Current 66 kA
Rated Voltage 690 VAC
Standards and Approvals IEC 309
Terminal Type Horizontal Rear Spread
Trip Unit Ekip Touch LSIG
Version Withdrawable

Description

<p>When it comes to ensuring robust and reliable circuit protection in industrial and commercial settings, the Motor Operated Air Circuit Breaker (ACB) is an essential component for maintaining electrical system integrity. Designed to handle demanding environments, this ACB offers a comprehensive solution for those looking to safeguard their electrical infrastructure without compromising on performance or safety.</p><p>The product supports a wide range of rated currents from 1600 to 4000 A, making it versatile enough to suit various applications. It&amp;#39;s engineered with a rated impulse withstand voltage of 12 kV and a rated insulation voltage of 1000 VAC, providing excellent protection against transient overvoltages. With its capability to operate at a rated voltage of up to 690 VAC, this ACB is well-suited for high-demand power systems.</p><p>One of the standout features is its Ekip Touch LSIG trip unit. This advanced trip unit offers precise control and monitoring capabilities, allowing users to tailor the protection settings according to specific needs. It effectively manages overloads, short circuits, and ground faults, enhancing both safety and reliability.</p><p>The breaker boasts an impressive breaking capacity of 66 kA along with a rated short time withstand current also at 66 kA. These specifications ensure that the device can handle substantial fault currents without damage or disruption to operations.</p><p>With three poles and an E4.2 frame size, this motor-operated ACB fits seamlessly into existing setups while offering flexibility in installation thanks to its horizontal rear spread terminal type. This configuration facilitates straightforward integration into your power distribution network.</p><p>Power loss is an important consideration in any electrical component; this ACB registers at just 900 W, minimizing energy wastage while maintaining efficiency across operations.</p><p>Compliance with IEC 309 standards underscores the product&amp;#39;s commitment to quality and safety protocols recognized internationally within the industry. Such adherence guarantees that you are investing in equipment that meets rigorous global benchmarks for performance and dependability.</p><p>In summary, whether you&amp;#39;re upgrading existing systems or planning new installations, this Motor Operated ACB provides solid technical specifications aligned with modern requirements for efficiency and resilience in power management systems.</p>